Skip to main content

Table 7 Parameters of push-out specimen used to verify formula

From: Methodology for calculating load capacity reduction and slip relationship of clustered group nail connectors

No

Data source

Nail size (diameter mm × height) (mm)

Nail layers

Nail layers spacing (D)

Concrete strength grade

GS1

Deng (Deng et al. 2022)

16 × 150

3

4D

C50

GS2

Deng (Deng et al. 2022)

16 × 150

3

6D

C50

GS3

Deng (Deng et al. 2022)

16 × 150

3

8D

C50

GS4

Deng (Deng et al. 2022)

16 × 150

5

4D

C50