Table 5 The SHM equipment and experiments

From: Review of data quality indicators and metrics, and suggestions for indicators and metrics for structural health monitoring

Monitoring Tool

What is record

Unit

How often it is recorded

What is computed

Unit

How often it is compute

Analysed

Accelerometer

Acceleration

cm/s2

permanently

Frequency

Hz

permanently

Permanently

Seismometers

Velocity

cm/s

each 5 years

Frequency

Hz

each 5 years

Punctually