Skip to main content

Table 1 Test parameters

From: Fatigue life prediction of stud shear connectors under corrosion-fatigue coupling effect

Name

Specimen set

Fatigue loads

Corrosive environment

Corrosion-fatigue test

CFP1

55%Pu

3.5%NaCl solution 400 mA

CFP2

40%Pu

3.5%NaCl solution 400 mA

CFP3

40%Pu

3.5%NaCl solution 100 mA