Table 8 Continuous scale DQ metric values for the permanent monitoring of the Z24 bridge

From: Review of data quality indicators and metrics, and suggestions for indicators and metrics for structural health monitoring

Indicator

Continuous scale-permanent

DQ u

S u

ω u

DQ u ω u

Accuracy

1

0.8

0.143

0.143

Precision

1

0.7

0.125

0.125

Consistency

1

0.3

0.054

0.054

Redundancy

1

0.5

0.089

0.089

Accessibility

1

0.7

0.125

0.125

Interoperability

1

0.1

0.018

0.018

Security

0

0.1

0.018

0.000

Traceability

1

0.3

0.054

0.054

Timeliness

1

0.7

0.125

0.125

Completeness

1

0.7

0.125

0.125

Relevancy

1

0.7

0.125

0.125

Total

 

5.6

1

0.982