Skip to main content

Table 5 Coefficients of the practical formula for cable force estimation

From: Cable force estimation of cables with small sag considering inclination angle effect

Boundary

Bending stiffness

a1

b1

c1

a2

b2

c2

Hinged-Hinged Cable

Large bending stiffness(0 ≤ ξ ≤ 18)

0.201

2.038

4.202

13.020

2.042

22.960

Medium bending stiffness(18 < ξ ≤ 210)

0.254

2.042

4.256

336.000

2.000

338.500

Small bending stiffness(ξ > 210)

0.258

2.045

4.256

34,040.000

2.000

32,740.000

Fixed-Fixed Cable

Large bending stiffness(0 ≤ ξ ≤ 18)

0.067

2.031

3.590

6.028

2.000

56.100

Medium bending stiffness(18 < ξ ≤ 210)

0.203

2.044

4.089

285.200

2.000

418.000

Small bending stiffness(ξ > 210)

0.259

2.038

4.255

34,080.000

2.000

3340.000