Skip to main content

Table 10 Force estimation result of Cable II

From: Cable force estimation of cables with small sag considering inclination angle effect

EC

Angle

(°)

FF

(Hz)

RCF

(MN)

Hinged-Hinged

Fixed-Fixed

Estimated

Tj(MN)

RE(%)

Tg(MN)

RE(%)

T1(MN)

RE(%)

\( {K}_{rot}^{\hbox{'}} \)

0

1.370

26.1325

26.9495

3.13

25.0188

−4.26

26.0010

−0.50

30

1.355

26.9647

3.18

25.0026

−4.32

25.9978

−0.52

60

1.322

27.0513

3.52

24.9984

−4.34

26.0330

−0.38

90

1.306

27.2820

4.40

25.1553

−3.74

26.2238

0.35

\( {K}_{rot}^{\hbox{'}\hbox{'}} \)

0

1.377

26.1325

27.2964

4.45

25.3490

−3.00

26.3397

0.79

30

1.362

27.2978

4.46

25.3211

−3.11

26.3237

0.73

60

1.330

27.4009

4.85

25.3361

−3.05

26.3768

0.93

90

1.314

27.6176

5.68

25.4811

−2.49

26.5546

1.62

\( {K}_{rot}^{\hbox{'}\hbox{'}\hbox{'}} \)

0

1.381

26.1325

27.4954

5.22

25.5384

−2.27

26.5340

1.54

30

1.366

27.4889

5.19

25.5038

−2.41

26.5107

1.45

60

1.334

27.5765

5.53

25.5058

−2.40

26.5949

1.60

90

1.317

27.7439

6.17

25.6038

−2.02

26.4739

1.29

  1. Note: EB denotes elastic boundary; FF denotes fundamental frequency; RCF denotes reference cable force; RE denotes relative error