Skip to main content

Table 8 Comparison of statistical analyses results between AASHTO and modified AASHTO spectra

From: Modified spectral format based on probability level using site-specific uniform hazard spectrum

Spectrum

Values of modifiers

Influence of modification factors on \( {C}_{sm}^{\ast } \) distribution

0.9 < \( {C}_{sm}^{\ast } \) <  1.5

\( {C}_{sm}^{\ast } \) < 0.9

Period Range 1: 0 to 0.5 s

 AASHTO spectrum

–

34.8%

59.3%

 Modified AASHTO spectrum

F0.2 = 1.3, F1.0 = 3.0, k = 0.75

55.7%

10.7%

Period range 2: 0.5 to 1.0 s

 AASHTO spectrum

–

11.6%

85.6%

 Modified AASHTO spectrum

F0.2 = 1.3, F1.0 = 3.0, k = 0.75

42.3%

3.8%

Period range 3: 1.0 to 2.0 s

 AASHTO spectrum

–

4.2%

94.1%

 Modified AASHTO spectrum

F0.2 = 1.3, F1.0 = 3.0, k = 0.75

43.4%

5.5%

Period range 4: 2.0 to 4.0 s

 AASHTO spectrum

–

2.6%

96.9%

 Modified AASHTO spectrum

F0.2 = 1.3, F1.0 = 3.0, k = 0.75

44.1%

9.3%

Period range 5: 4.0 to 5.0 s

 AASHTO spectrum

–

2.3%

97.2%

 Modified AASHTO spectrum

F0.2 = 1.3, F1.0 = 3.0, k = 0.75

42.9%

5.7%